Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
1.
Endoscopy ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657660

RESUMO

INTRODUCTION: The environmental impact of endoscopy, including small-bowel capsule endoscopy (SBCE), has gained attention due to its contribution to the global carbon footprint. This study aimed to evaluate the greenhouse gas (GHG) emissions (kgCO2e) of SBCE, including devices life cycle and capsule journey. METHODS: SBCE devices (3 brands) were evaluated using life cycle assessment methodology (ISO 14040), including patient travelling, bowel preparation, capsule examination and video recording. A survey was conducted on 120 patients undergoing a SBCE to gather data on their transportation, activities during the procedure, and awareness of pollution generated and on 87 physicians reading capsules. RESULTS: For the 3 different capsules, the weight was 4 g (3.9-5.2% of total), while 43 to 119 g were attributed for packaging (9-97%) including 5 g of deactivation magnets (4-6%) and 11 to 50 g for instruction forms (40%). A full SBCE generated between 19 and 20 kgCO2e, including 0.04 kgCO2e (0.2%) for the capsule itself and 18 kgCO2e related to patient travelling (94.7%). Capsule retrieval would add 0.98 kgCO2e using dedicated devices. Capsule deconstruction revealed components (e.g. Neodymium) that are prohibited from environmental disposal. 76% of patients were not aware of the illegal nature of flushing capsules, and 63% would be willing to retrieve it. Data storage and physician impact were negligible. CONCLUSION: The GHG emission of SBCE is mainly determined by patient travelling. The capsule device itself has a comparably low carbon footprint. Considering capsule components disposal is illegal, retrieval of the capsule seems crucial but increasing device-related emissions.

2.
Scand J Gastroenterol ; 59(5): 608-614, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38333956

RESUMO

BACKGROUND AND AIMS: Accurate polyp size estimation during colonoscopy has an impact on clinical decision-making. A laser-based virtual scale endoscope (VSE) is available to allow measuring polyp size using a virtual adaptive scale. This study evaluates video-based polyp size measurement accuracy among expert endoscopists using either VSE or visual assessment (VA) with either snare as reference size or without any reference size information. METHODS: A prospective, video-based study was conducted with 10 expert endoscopists. Video sequences from 90 polyps with known reference size (fresh specimen measured using calipers) were distributed on three different slide sets so that each slide set showed the same polyp only once with either VSE, VA or snare-based information. A slide set was randomly assigned to each endoscopist. Endoscopists were asked to provide size estimation based on video review. RESULTS: Relative accuracies for VSE, VA, and snare-based estimation were 75.1% (95% CI [71.6-78.5]), 65.0% (95% CI [59.5-70.4]) and 62.0% (95% CI [54.8-69.0]), respectively. VSE yielded significantly higher relative accuracy compared to VA (p = 0.002) and to snare (p = 0.001). A significantly lower percentage of polyps 1-5 mm were misclassified as >5 mm using VSE versus VA and snare (6.52% vs. 19.6% and 17.5%, p = 0.004) and a significantly lower percentage of polyps >5 mm were misclassified as 1-5 mm using VSE versus VA and snare (11.4% vs. 31.9% and 14.9%, p = 0.038). CONCLUSIONS: Endoscopists estimate polyp size with the highest accuracy when virtual adaptive scale information is displayed. Using a snare to assist sizing did not improve measurement accuracy compared to displaying visual information alone.


Assuntos
Pólipos do Colo , Colonoscopia , Gravação em Vídeo , Humanos , Estudos Prospectivos , Colonoscopia/métodos , Pólipos do Colo/patologia , Competência Clínica , Masculino , Feminino
3.
Gastroenterology ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38331204

RESUMO

BACKGROUND & AIMS: Artificial intelligence (AI)-based optical diagnosis systems (CADx) have been developed to allow pathology prediction of colorectal polyps during colonoscopies. However, CADx systems have not yet been validated for autonomous performance. Therefore, we conducted a trial comparing autonomous AI to AI-assisted human (AI-H) optical diagnosis. METHODS: We performed a randomized noninferiority trial of patients undergoing elective colonoscopies at 1 academic institution. Patients were randomized into (1) autonomous AI-based CADx optical diagnosis of diminutive polyps without human input or (2) diagnosis by endoscopists who performed optical diagnosis of diminutive polyps after seeing the real-time CADx diagnosis. The primary outcome was accuracy in optical diagnosis in both arms using pathology as the gold standard. Secondary outcomes included agreement with pathology for surveillance intervals. RESULTS: A total of 467 patients were randomized (238 patients/158 polyps in the autonomous AI group and 229 patients/179 polyps in the AI-H group). Accuracy for optical diagnosis was 77.2% (95% confidence interval [CI], 69.7-84.7) in the autonomous AI group and 72.1% (95% CI, 65.5-78.6) in the AI-H group (P = .86). For high-confidence diagnoses, accuracy for optical diagnosis was 77.2% (95% CI, 69.7-84.7) in the autonomous AI group and 75.5% (95% CI, 67.9-82.0) in the AI-H group. Autonomous AI had statistically significantly higher agreement with pathology-based surveillance intervals compared to AI-H (91.5% [95% CI, 86.9-96.1] vs 82.1% [95% CI, 76.5-87.7]; P = .016). CONCLUSIONS: Autonomous AI-based optical diagnosis exhibits noninferior accuracy to endoscopist-based diagnosis. Both autonomous AI and AI-H exhibited relatively low accuracy for optical diagnosis; however, autonomous AI achieved higher agreement with pathology-based surveillance intervals. (ClinicalTrials.gov, Number NCT05236790).

4.
Endoscopy ; 56(5): 355-363, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38278158

RESUMO

BACKGROUND: Gastrointestinal (GI) endoscopy is one of healthcare's main contributors to climate change. We aimed to assess healthcare professionals' attitudes and the perceived barriers to implementation of sustainable GI endoscopy. METHODS: The LEAFGREEN web-based survey was a cross-sectional study conducted by the European Society of Gastrointestinal Endoscopy (ESGE) Green Endoscopy Working Group. The questionnaire comprised 39 questions divided into five sections (respondent demographics; climate change and sustainability beliefs; waste and resource management; single-use endoscopes and accessories; education and research). The survey was available via email to all active members of the ESGE and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) in March 2023. RESULTS: 407 respondents participated in the survey (11% response rate). Most participants (86%) agreed climate change is real and anthropogenic, but one-third did not consider GI endoscopy to be a significant contributor to climate change. Improvement in the appropriateness of endoscopic procedures (41%) and reduction in single-use accessories (34%) were considered the most important strategies to reduce the environmental impact of GI endoscopy. Respondents deemed lack of institutional support and knowledge from staff to be the main barriers to sustainable endoscopy. Strategies to reduce unnecessary GI endoscopic procedures and comparative studies of single-use versus reusable accessories were identified as research priorities. CONCLUSIONS: In this survey, ESGE and ESGENA members acknowledge climate change as a major threat to humanity. Further improvement in sustainability beliefs and professional attitudes, reduction in inappropriate GI endoscopy, and rational use of single-use accessories and endoscopes are critically required.


Assuntos
Atitude do Pessoal de Saúde , Endoscopia Gastrointestinal , Humanos , Estudos Transversais , Feminino , Masculino , Inquéritos e Questionários , Adulto , Mudança Climática , Pessoa de Meia-Idade , Conhecimentos, Atitudes e Prática em Saúde , Endoscópios Gastrointestinais
5.
Pain Pract ; 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38251757

RESUMO

BACKGROUND: Pain in the head and the face is highly prevalent but may have changed during the past years. This study aimed to analyze changes in the prevalence of pain in the head and the face in Switzerland from 1997 to 2017. METHODS: This is a secondary analysis of data collected in the Swiss Health Surveys of 1997-2017. Included persons were 15 years and older. Besides studying demographic data, we analyze the item assessing the presence of "headache, pressure in the head, or facial pain" during the past 4 weeks. Percentages with their Wilson confidence intervals are reported for each response option of categorical variables. Moreover, we calculate the age-standardized number of persons affected by the pain. RESULTS: While 41% reported head and face pain in 1997, the proportion dropped to 31% in 2017. There was a decrease of 19.5% in women and 29.4% in men; after age standardization, the decrease was 16.5% in women and 25.4% in men. The most considerable numerical changes in the percentages of women with pain occurred in those aged 55-69 and 85 and above. In men, the changes were not limited to specific age groups. CONCLUSIONS: The proportion of people reporting headaches, pressure in the head, or facial pain has dropped in Switzerland from 1997 to 2017. However, in women, the prevalence diminished more strongly and consistently in the middle-aged and the elderly than in the young.

7.
Clin Gastroenterol Hepatol ; 22(3): 552-561.e4, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37871841

RESUMO

BACKGROUND & AIMS: Thermal treatment of the defect margin after endoscopic mucosal resection (EMR) of large nonpedunculated colorectal lesions reduces the recurrence rate. Both snare tip soft coagulation (STSC) and argon plasma coagulation (APC) have been used for thermal margin treatment, but there are few data directly comparing STSC with APC for this indication. METHODS: We performed a randomized 3-arm trial in 9 US centers comparing STSC with APC with no margin treatment (control) of defects after EMR of colorectal nonpedunculated lesions ≥15 mm. The primary end point was the presence of residual lesion at first follow-up. RESULTS: There were 384 patients and 414 lesions randomized, and 308 patients (80.2%) with 328 lesions completed ≥1 follow-up. The proportion of lesions with residual polyp at first follow-up was 4.6% with STSC, 9.3% with APC, and 21.4% with control subjects (no margin treatment). The odds of residual polyp at first follow-up were lower for STSC and APC when compared with control subjects (P = .001 and P = .01, respectively). The difference in odds was not significant between STSC and APC. STSC took less time to apply than APC (median, 3.35 vs 4.08 minutes; P = .019). Adverse event rates were low, with no difference between arms. CONCLUSIONS: In a randomized trial STSC and APC were each superior to no thermal margin treatment after EMR. STSC was faster to apply than APC. Because STSC also results in lower cost and plastic waste than APC (APC requires an additional device), our study supports STSC as the preferred thermal margin treatment after colorectal EMR. (Clinicaltrials.gov, Number NCT03654209.).


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Pólipos do Colo/patologia , Colonoscopia/métodos , Coagulação com Plasma de Argônio , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/etiologia , Ressecção Endoscópica de Mucosa/métodos
8.
Gastrointest Endosc ; 99(2): 177-185, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37500019

RESUMO

BACKGROUND AND AIMS: Video analysis has emerged as a potential strategy for performance assessment and improvement. We aimed to develop a video-based skill assessment tool for peroral endoscopic myotomy (POEM). METHODS: POEM was deconstructed into basic procedural components through video analysis by an expert panel. A modified Delphi approach and 2 validation exercises were conducted to refine the POEM assessment tool (POEMAT). Twelve assessors used the final POEMAT version to grade 10 videos. Fully crossed generalizability (G) studies investigated the contributions of assessors, endoscopists' performance, and technical elements to reliability. G coefficients below .5 were considered unreliable, between .5 and .7 as modestly reliable, and above .7 as indicative of satisfactory reliability. RESULTS: After task deconstruction, discussions, and the modified Delphi process, the final POEMAT comprised 9 technical elements. G analysis showed low variance for endoscopist performance (.8%-24.9%) and high interrater variability (range, 63.2%-90.1%). The G score was moderately reliable (≥.60) for "submucosal tunneling" and "myotomy" and satisfactorily reliable (≥.70) for "active hemostasis" and "mucosal closure." CONCLUSIONS: We developed and established initial content and response process validity evidence for the POEMAT. Future steps include appraisal of the tool using a wider range of POEM videos to establish and improve the discriminative validity of this tool.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Acalasia Esofágica , Miotomia , Cirurgia Endoscópica por Orifício Natural , Humanos , Acalasia Esofágica/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento , Esfíncter Esofágico Inferior
9.
Scand J Gastroenterol ; 59(1): 112-117, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37743643

RESUMO

INTRODUCTION: Serrated lesions (SLs) including traditional serrated adenomas (TSA), large hyperplastic polyps (HP) and sessile serrated lesions (SSLs) are associated with high incomplete resection rates. Margin ablation combined with EMR (EMR-T) has become routine to reduce local recurrence while cold snare polypectomy (CSP) is becoming recognized as equally effective for large SLs. Our aim was to evaluate local recurrence rates (LRR) and the use of margin ablation in preventing recurrence in a retrospective cohort study. METHODS: Patients undergoing resection of ≥15 mm colorectal SLs from 2010-2022 were identified through a pathology database and electronic medical records search. Hereditary CRC syndromes, first follow-up > 18 months or no follow-up, surgical resection were excluded. Primary outcome was LRRs (either histologic or visual) during the first 18-month follow-up. Secondary outcomes were LRRs according to size, and resection technique. RESULTS: 191 polyps in 170 patients were resected (59.8% women; mean age, 65 years). The mean size of polyps was 22.4 mm, with 107 (56.0%) ≥20 mm. 99 polyps were resected with EMR, 39 with EMR-T, and 26 with CSP. Mean first surveillance was 8.2 mo. Overall LRR was 18.8% (36/191) (16.8% for ≥20 mm, 17.9% for ≥30 mm). LRR was significantly lower after EMR-T when compared with EMR (5.1% vs. 23.2%; p = 0.013) or CSP (5.1% vs. 23.1%; p = 0.031). There was no difference in LRR between EMR without margin ablation and CSP (p = 0.987). CONCLUSION: The local recurrence rate for SLs ≥15 mm is high with 18.8% overall recurrence. EMR with thermal ablation of the margins is superior to both no ablation and CSP in reducing LRRs.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Feminino , Idoso , Masculino , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/métodos , Estudos Retrospectivos , Adenoma/cirurgia , Adenoma/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Ressecção Endoscópica de Mucosa/métodos
10.
12.
Gastrointest Endosc ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37993062

RESUMO

BACKGROUND AND AIMS: Endocuff VisionTM has been designed to enhance mucosal visualization thereby improving detection of (pre-)malignant colorectal lesions. This multicenter, international, back-to-back, randomized colonoscopy trial compared adenoma detection rate (ADR) and adenoma miss rate (AMR) between Endocuff Vision-assisted colonoscopy (EVC) and conventional colonoscopy (CC). METHODS: Patients aged 40-75 years referred for non-immunochemical fecal occult blood test-based screening, surveillance, or diagnostic colonoscopy were included at ten hospitals and randomized into four groups: Group 1; 2xCC, Group 2; CC followed by EVC, Group 3; EVC followed CC and Group 4; 2xEVC. Primary outcomes included ADR and AMR. RESULTS: A total of 717 patients were randomized of which 661 patients (92.2%) had one and 646 (90.1%) patients had two completed back-to-back colonoscopies. EVC did not significantly improve ADR compared to CC (41.1% [95%-CI;36.1-46.3] versus 35.5% [95%-CI;30.7-40.6], respectively, P=0.125), but EVC did reduced AMR by 11.7% (29.6% [95%-CI;23.6-36.5] versus 17.9% [95%-CI;12.5-23.5], respectively, P=0.049). AMR of 2xCC compared to 2xEVC was also not significantly different (25.9% [95%-CI;19.3-33.9] versus 18.8% [95%-CI;13.9-24.8], respectively, P=0.172). Only 3.7% of the polyps missed during the first procedures had advanced pathologic features. Factors affecting risk of missing adenomas were age (P=0.002), Boston Bowel Preparation Scale (P=0.008) and region where colonoscopy was performed (P<0.001). CONCLUSIONS: Our trial shows that EVC reduces the risk of missing adenomas but does not lead to a significant improved ADR. Remarkably, 25% of adenomas are still missed during conventional colonoscopies, which is not different from miss rates reported 25 years ago; reassuringly, advanced features were only found in 3.7% of these missed lesions. TRAIL REGISTRATION NUMBER: NCT03418948.

15.
Gastroenterol Hepatol (N Y) ; 19(4): 233-236, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37705842
16.
Sci Rep ; 13(1): 13944, 2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37626074

RESUMO

Cerebral blood flow differs between migraine patients and healthy controls during attack and the interictal period. This study compares the brain perfusion of episodic migraine patients and healthy controls and investigates the influence of anodal transcranial direct current stimulation (tDCS) over the occipital cortex. We included healthy adult controls and episodic migraineurs. After a 28-day baseline period and the baseline visit, migraine patients received daily active or sham anodal tDCS over the occipital lobe for 28 days. All participants underwent a MRI scan at baseline; migraineurs were also scanned shortly after the stimulation period and about five months later. At baseline, brain perfusion of migraine patients and controls differed in several areas; among the stimulated areas, perfusion was increased in the cuneus of healthy controls. At the first visit, the active tDCS group had an increased blood flow in regions processing visual stimuli and a decreased perfusion in other areas. Perfusion did not differ at the second follow-up visit. The lower perfusion level in migraineurs in the cuneus indicates a lower preactivation level. Anodal tDCS over the occipital cortex increases perfusion of several areas shortly after the stimulation period, but not 5 months later. An increase in the cortical preactivation level could mediate the transient reduction of the migraine frequency.Trial registration: NCT03237754 (registered at clincicaltrials.gov; full date of first trial registration: 03/08/2017).


Assuntos
Transtornos de Enxaqueca , Estimulação Transcraniana por Corrente Contínua , Adulto , Humanos , Encéfalo , Circulação Cerebrovascular , Transtornos de Enxaqueca/diagnóstico por imagem , Transtornos de Enxaqueca/terapia , Perfusão
17.
Endoscopy ; 55(9): 865-870, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37207666

RESUMO

BACKGROUND: Delayed bleeding is among the most common adverse events associated with endoscopic mucosal resection (EMR) of nonampullary duodenal polyps. We evaluated the rate of delayed bleeding and complete defect closure using a novel through-the-scope (TTS) suturing system for the closure of duodenal EMR defects. METHODS: We reviewed the electronic medical records of patients who underwent EMR for nonampullary duodenal polyps of ≥ 10 mm and prophylactic defect closure with TTS suturing between March 2021 and May 2022 at centers in the USA. We evaluated the rates of delayed bleeding and complete defect closure. RESULTS: 36 nonconsecutive patients (61 % women; mean [SD] age, 65 [12] years) underwent EMR of ≥ 10-mm duodenal polyps followed by attempted defect closure with TTS suturing. The mean (SD) lesion size was 29 (19) mm, defect size was 37 (25) mm; eight polyps (22 %) involved > 50 % of the lumen circumference. Complete closure was achieved in all cases (78 % with TTS suturing alone), using a median of one TTS suturing kit. There were no cases of delayed bleeding and no adverse events attributed to application of the TTS suturing device. CONCLUSION: Prophylactic closure of nonampullary duodenal EMR defects using TTS suturing resulted in a high rate of complete closure and no delayed bleeding events.


Assuntos
Neoplasias Duodenais , Ressecção Endoscópica de Mucosa , Humanos , Feminino , Idoso , Masculino , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Estudos de Coortes , Resultado do Tratamento , Neoplasias Duodenais/cirurgia , Neoplasias Duodenais/patologia , Estudos Retrospectivos , Pólipos Intestinais/patologia , Estudos Multicêntricos como Assunto
18.
Gastrointest Endosc ; 98(1): 122-129, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36889364

RESUMO

BACKGROUND AND AIMS: Large colon polyps removed by EMR can be complicated by delayed bleeding. Prophylactic defect clip closure can reduce post-EMR bleeding. Larger defects can be challenging to close using through-the-scope clips (TTSCs), and proximal defects are difficult to reach using over-the-scope techniques. A novel, through-the-scope suturing (TTSS) device allows direct closure of mucosal defects without scope withdrawal. The goal of this study was to evaluate the rate of delayed bleeding after the closure of large colon polyp EMR sites with TTSS. METHODS: A multicenter retrospective cohort study was performed involving 13 centers. All defect closure by TTSS after EMR of colon polyps ≥2 cm from January 2021 to February 2022 were included. The primary outcome was rate of delayed bleeding. RESULTS: A total of 94 patients (52% female; mean age, 65 years) underwent EMR of predominantly right-sided (n = 62 [66%]) colon polyps (median size, 35 mm; interquartile range, 30-40 mm) followed by defect closure with TTSS during the study period. All defects were successfully closed with TTSS alone (n = 62 [66%]) or with TTSS and TTSCs (n = 32 [34%]), using a median of 1 (interquartile range, 1-1) TTSS system. Delayed bleeding occurred in 3 patients (3.2%), with 2 requiring repeated endoscopic evaluation/treatment (moderate). CONCLUSION: TTSS alone or with TTSCs was effective in achieving complete closure of all post-EMR defects, despite a large lesion size. After TTSS closure with or without adjunctive devices, delayed bleeding was seen in 3.2% of cases. Further prospective studies are needed to validate these findings before wider adoption of TTSS for large polypectomy closure.


Assuntos
Pólipos do Colo , Ressecção Endoscópica de Mucosa , Idoso , Feminino , Humanos , Masculino , Colo/cirurgia , Colo/patologia , Pólipos do Colo/patologia , Colonoscopia/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/etiologia , Estudos Retrospectivos , Instrumentos Cirúrgicos
19.
J Womens Health (Larchmt) ; 32(5): 598-607, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36897310

RESUMO

Background: This study examines endometriosis (EM) features in women with EM and migraines (MG) (EM-MG) and women with EM alone (EM-O). The comorbidity of MG and EM is well known. However, knowledge about differences in symptoms, clinical manifestations, and severity of EM between EM-MG and EM-O is scarce. Materials and Methods: We conducted a cross-sectional observational study of premenopausal patients with biopsy-confirmed EM treated in our department from 2015 to 2021. All patients underwent surgical treatment for EM. Information about infiltration depth and localization of EM was available. We interviewed patients using a structured questionnaire that includes questions about clinical characteristics, symptoms, and treatment history. We reported categorical variables as frequencies and continuous variables as means with standard deviations. We compared subgroups (EM-MG vs. EM-O) using an independent sample t-test, the Wilcoxon-Mann-Whitney test, chi-square test, and Fisher's exact test. The significance level was 0.05. Results: We included 344 participants: 250 with EM-O and 94 with EM-MG. EM-MG had less severe revised American Society of Reproductive Medicine scores (p = 0.023), more deliveries (p = 0.009), more and higher scores of dysmenorrhea at menarche (p = 0.044; p = 0.036), prolonged heavy menstrual bleeding (p = 0.009), more and prolonged pain during menstrual bleeding (p = 0.011, p = 0.039), and more dyschezia (p < 0.001) compared with EM-O. Conclusion: Migraineurs experienced more intense EM symptoms at lower EM stages. This discrepancy strongly indicates pain sensitizations and a lower pain threshold in patients with EM-MG. Knowledge about EM features allows early diagnosis and treatment of women with potential EM-MG, both highly disabling conditions. Clinical Trials.gov (NCT04816357).


Assuntos
Endometriose , Humanos , Feminino , Endometriose/complicações , Endometriose/epidemiologia , Estudos Transversais , Biópsia , Constipação Intestinal , Dismenorreia/epidemiologia , Dismenorreia/etiologia
20.
J Neurosci Res ; 101(6): 815-825, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36688271

RESUMO

This study investigated differences in the concentration of gamma-aminobutyric acid (GABA) and the combination of glutamine and glutamate (as GLX) in the early visual cortex of patients with episodic migraine and the influence of transcranial direct current stimulation (tDCS) on GABA and GLX. In this single-blind, sham-controlled trial, we randomly assigned patients with episodic migraine to receive daily anodal tDCS or sham stimulation. In addition, we included healthy controls. We acquired proton MR spectroscopy data of the visual cortex with 3 Tesla MRI at baseline and from migraine patients directly after the stimulation period and 4 months later. In 22 migraineurs and 25 controls, the GABA and the GLX concentrations did not differ at baseline between the groups. tDCS resulted in reduced concentrations of GABA but not GLX or the migraine frequency directly after the stimulation period, but not 4 months later. The changes in the levels of GABA in the early visual cortex of patients with episodic migraine in the interictal period suggest an effect of tDCS that allowed for subsequent changes in the migraine frequency. However, we might have missed relevant variations in the concentrations of these neurotransmitters during the follow-up period, as changes in migraine frequency appeared after the first MRI and disappeared before the second.


Assuntos
Transtornos de Enxaqueca , Estimulação Transcraniana por Corrente Contínua , Humanos , Glutamina , Estimulação Transcraniana por Corrente Contínua/métodos , Método Simples-Cego , Ácido Glutâmico , Transtornos de Enxaqueca/terapia , Ácido gama-Aminobutírico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...